Bay
Package Size 44.00cm * 40.00cm * 35.00cm Package Gross Weight 25.000kg Bay O Net tap changer switch for oil transformer
Basic Info.
Model NO. | PRNT4-40.5/16 |
Arc-extinguishing Medium | Oil-immersed Type |
Installation | Insert |
Structure | MCB |
Poles Number | 1 |
Type | Fuse |
Function | Overcurrent Protection |
Certification | ISO9001-2000, TUV |
Usage | High Voltage Equipment |
Fusing Speed | FF |
HS | 8535100000 |
Standard | Germany DIN Standard |
Fusing Device | Link Break |
Shape | Insert |
Model No. | Prnt4-40.5/16 |
Transport Package | Foam Carton and Wooden Packing |
Specification | 40.5Kv |
Trademark | Wuhuan |
Origin | Xi′ an China |
HS Code | 8535100000 |
Production Capacity | 80000 Per Month |
Packaging & Delivery
Package Size 44.00cm * 40.00cm * 35.00cm Package Gross Weight 25.000kgProduct Description
Bay O Net tap changer switch for oil transformer This kind of switch applies to single-phase, three phase , combination oil-immersed transformer electrical power with frequency of 50HZ,,60HZ,rated voltage of 10KV,35KV,rated current of 30A ~500A; the voltage-regulating mode are: central part, terminal point neutral point, which can be directly fixed on the tank cover of the transformer, exchange under the off-circuit condition.Bay- O-Net Assembly is the brief element of oil-transformer, to protect the equipment when over-current. When install the fuse wire in it, the Bay-O-Net will provide the safe, highly efficient protection, according to the current, oil-femperature.The Bay-O-Net Assembly is suitable for current sensing fuse wire, dual sensing fuse wire, dual element fuse wire, and ELSP current-limiting backup fuse, etc.It is suitable for high-voltage power system with alternating current of 50Hz,standard voltage of 15. 5kV, current rating of 140A. It must be combining with MagnX Interrupter of ELSP Current-Limiting Backup Fuse to protect transformer from overload and short circuit.Bay-o-net Assembly is the brief element of oil-transformer, to protect the equipment when over-current. When install the fuse wire in it, the Bay-o-net will provide the safe, highly efficient protection, according to the current, oil temperature.The Bay-o-net Assembly is suitable for current sensing fuse wire, dual sensing fuse wire, dual element fuse wire, and ELSP current-limiting backup fuse,etc.It is suitable for high-voltage power system with alternating current of 50HZ, standard voltage of 15.5kv, current rating of 140A. It must be combining with Magn X Interrupter of ELSP Current-limiting Backup Fuse to protect transformer from overload and short circuit.
1. Model and meaning :2. This product is composed of overload protection fuse and fuse holder.
2.1 Basic engineering data:
Model number | Rating current of fusible core (A) | Service enviornment | Rating breaking current (KA) |
PRNT4-15.5 PRNT4-24 PRNT4-40.5 | 5, 6.3, 10 , 16, 25, 40, 50, 63 100, 140 | in transformer oil | 2.5 |
Note:Dual fuse maximum 63A
2.2 See picture 1 for the size and installation of the overload protection fuse
Picture 1,XRNT4-15.5 High voltage fuses for overload protection of oil immersed transformer .
2.3 See picture 2 and picture 3 for the dimension and installation of the plug-in fuse holder
3. Installation steps of fuse wire:4. Time-current characteristic curve of bay-o-net fuse as below :
Transformer capacity (KVA) | 12KV power system | 24KV power system | 40.5KV power system | |||
overload fuse | Backup current limiting fuse | overload fuse | Backup current limiting fuse | overload fuse | Backup current limiting fuse | |
100 | PRNT4-15.5/10 | XRNT4-15.5/31.5 | PRNT4-24/6.3 | XRNT4-24/16 | PRNT4-40.5/5 | XRNT4-40.5/10 |
200 | PRNT4-15.5/16 | XRNT4-15.5/40 | PRNT4-24/10 | XRNT4-24/20 | PRNT4-40.5/8 | XRNT4-40.5/16 |
315 | PRNT4-15.5/25 | XRNT4-15.5/50 | PRNT4-24/16 | XRNT4-24/32 | PRNT4-40.5/10 | XRNT4-40.5/20 |
400 | PRNT4-15.5/32 | XRNT4-15.5/63 | PRNT4-24/20 | XRNT4-24/40 | PRNT4-40.5/16 | XRNT4-40.5/31.5 |
500 | PRNT4-15.5/40 | XRNT4-15.5/80 | PRNT4-24/25 | XRNT4-24/50 | PRNT4-40.5/20 | XRNT4-40.5/40 |
630 | PRNT4-15.5/50 | XRNT4-15.5/100 | PRNT4-24/31.5 | XRNT4-24/63 | PRNT4-40.5/25 | XRNT4-40.5/50 |
800 | PRNT4-15.5/65 | XRNT4-15.5/125 | PRNT4-24/40 | XRNT4-24/80 | PRNT4-40.5/25 | XRNT4-40.5/50 |
1000 | PRNT4-15.5/80 | XRNT4-15.5/150 | PRNT4-24/50 | XRNT4-24/100 | PRNT4-40.5/31.5 | XRNT4-40.5/63 |
1250 | PRNT4-15.5/100 | XRNT4-15.5/175 | PRNT4-24/65 | XRNT4-24/125 | PRNT4-40.5/31.5 | XRNT4-40.5/63 |
1600 | PRNT4-15.5/140 | XRNT4-15.5/200 | PRNT4-24/80 | XRNT4-24/150 | PRNT4-40.5/40 | XRNT4-40.5/80 |
2000 | XRNT4-15.5/250 | PRNT4-24/100 | XRNT4-24/200 | PRNT4-40.5/50 | XRNT4-40.5/125 | |
250 | PRNT4-40.5/65 | SRNT4-40.5/125 |
Model and meaning